NYC 9/11 Public Portal Document
I Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
'ace Analytical____ ____
Method 8290 Analysis Results
Tet: 612-607-1700
Fax: 612- 607-6444
Client-ATC
Client's Sample ID ATC-1220-STY-DX2
Lab Sample ID 103234019
Filename F11228B_14
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/20/2001
ICAL Date 11/19/2001 Received 12/21/2001
CCal Filename(s) F11228B_01 & F11228B_16 Extracted 12/23/2001
Method Blank ID BLANK-1389 Analyzed 12/29/2001 08:09
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2.3,7.8-TCDF ■ ND 0.0030 A 2,3,7,8-TCDF-13C . 2.00 60
I Total TCDF
2,3,7.8-TCDD
ND
ND
0.0020
0.0034 A
2,3,7,8-TCDD-13C
1,2,3.7,8-PeCDF-13C
2,3,4,7,8-PeCDF-13C
2.00
2.00
2.00
75
64
64
Total TCDD' 0.0098 0.0020 J 1,2,3,7,8-PeCDD-13C 2.00 80
1,2.3.4,7,8-HxCDF-13C 2.00 77
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF--13C 2.00 73
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6.7.8-HxCDF-13C 2.00 71
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 77
1,2,3,4,7,8-HxCDD-13C 2.00 98
1.2,3,7,8-PeCDD ND 0.0100 1,2.3,6,7,8-HxCDD-13C 2.00 79
Total PeCDD ND 0.0100 1,2,3,4,6.7.8-HpCDF-13C 2.00 65
1^,3,4,7,8.9‘HpCDF-13C 2.00 69
1.2,3,4,7.8-HxCDF ND 0.0100 1.2,3,4,6,7,8-HpCDD-13C 2.00 70
J 1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 78
2.3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2.3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1.2.3.4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 73
1,2,3.6,7.8-HxCDD ND 0.0100
3 1,2,3.7,8,9-HxCDD
Total HxCDD
ND
0.0370
0.0100
0.0100 J
1,2,3.4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
; i 1,2,3.4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00030 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
a 1,2,3.4,6,7,8-HpCDD
Total HpCDD
OCDF
0.0200
0.0370
ND
0.0100 J
0.0100 J
0.0200
OCDD 0.1100 0.0200
I LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis
. •] * = See Discussion
Report No.... 01-1052541
•■•■I
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003432737
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008