NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
yceAnalytical''_________ _ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-1220-STY-DX1
Lab Sample ID 103234001
Filename F11228B_13
I Injected By
Total Amount Extracted
% Moisture
BAL
1 m2
NA
Matrix
Dilution
WIPE
NA
I Dry Weight Extracted
ICAL Date
CCal Filename(s)
NA
11/19/2001
F11228B_01 &F11228B_16
Collected
Received
Extracted
.12/20/2001
12/21/2001
12/23/2001
Method Blank ID BLANK-1389 Analyzed 12/29/2001 07:19
Native Cone EWIPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00230 A 2,3,7,8-TCDF-13C 2.00 59
i Total TCDF
2,3,7,8-TCDD
ND _
NO
0.00200
0.00220 A
2,3,7,8-TCDD-13C
1,2,3.7,8-PeCDF-13C
2,3,4,7,8-PeCDF-13C
- 2.00
2.00
2.00
72
65
66
Total TCDD 0.0092 0.00200 J 1.2,3,7,8-PeCDD-13C 2.00 81
1,2,3,4,7,8-HxCDF-13C 2.00 65
1,2,3,7.8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 70
2.3,4.7,8-PeCDF ND 0,01000 2,3,4,6,7,8-HxCDF-13C 2.00 70
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 72
1,2,3,4,7,8-HxCDD-13C 2.00 95
1.2.3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 78
Total PeCDD 0.0350 0.01000 J 1,2.3,4,6,7,8-HpCDF-13C 2.00 83
1,2,3,4,7,8,9-HpCDF-13C 2.00 80
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 95
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 74
2,3,4,6.7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2,00 NA
1,2,3.4.7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 73
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD 0.0550 0.01000
1.2.3,4,6,7.8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
J 1.2.3.4,7,8,9-HpCDF
Total HpCDF
ND
ND
0.01000
0.01000
Equivalence: 0.000038 ng/m2
(Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
i Total HpCDD
OCDF
0.0130
ND
0.01000 J
0.02000
OCDD 0.0380 0.02000 J
3 Cone = Concentration (Totals include 2,3,7,8-substituted isomers)
LRL = Lower Reporting Limit
I = Interference
EM PC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 01-1052541
3 REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003432736
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240855
OCR can misread numbers and units. Confirm readings against the page image before using them.