we Analytical_________ _ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612-607-6444
Client-ATC
Client's Sample ID ATC-1220-STY-DX4
Lab Sample ID 103234035
Filename F20103A_10
I Injected By
Total Amount Extracted
% Moisture
BAL
1 m2
NA
Matrix
Dilution
WIPE
NA
Dry Weight Extracted NA Collected 12/20/2001
ICAL Date 01/02/2002 Received 12/21/2001
CCal Filename(s) F20102A_22 & F20103B_01 Extracted 12/23/2001
Method Blank ID BLANK-1389 Analyzed 01/03/2002 15:38
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF 0.00200 2,3,7,8-TCDF-13C 2.00 85
I Total TCDF
2,3,7,8-TCDD
ND
ND
0.00200
0.00200
2,3,7.8-TCDD-13C
1,2,3,7,B-PeCDF-13C
2,3,4,7,8-PeCDF-13C
2.00
2.00
2.00
79
93
93
a Total TCDD
1,2,3,7,8-PeCDF
- 2,3,4,7,8-PeCDF
ND
ND
ND
0.00200
0.01000
0.01000
1,2,3,7,8-PeCDD-13C
1,2,3,4,7,8-HxCDF-13C
1,2,3,6,7,8-HxCDF-13C
2,3,4,6,7,8-HxCDF-13C
2.00
2.00
2.00
2.00
97
90
86
93
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 102
1,2,3,4,7,8-HXCDD-13C 2.00 110
1,2.3,7.8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 89
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 110
1,2,3,4,7,8,9-HpCDF-13C 2.00 128
1,2.3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 128
ti
1.2.3,6.7,8-HxCDF ND 0.01000 OCDD-13C 4.00 122
2,3,4,6,7,8-HxCDF ND 0.01000
PI 1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
c;
1,2,3,4,7,8-HxCDD ND 0.01000 2,3.7,8-TCDD-37CI4 0.20 80
1,2,3,6,7,8-HxCDD ND 0.01000
I 1,2,3,7,8,9-HxCDD
Total HxCDD
ND
ND
0.01000
0.01000
1,2,3,4,6.7,B-HpCDF ND 0.01000 Total 2,3.7,8-TCDD
1,2,3,4,7,8.9-HpCDF ND 0.01000 Equivalence; 0.00 ng/m2
J Total HpCDF • ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND - 0.01000
Total HpCDD ND - 0.01000
OCDF ND 0.02000
OCDD ND 0.02000
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-suDstituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No....01-1052541
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.