NYC 9/11 Public Portal Document
104 East 25th St
New York, New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
ASSOCIATES INC.
January 29,2002
Mr. Bernard P. Orlan
Director, En'vironmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Metals & Mercury Vapor
Stuyvesant High School
ATC Project No. 15-19125-0246
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to pro’vide this report of air sampling for metals in
airborne dust and mercury (Hg) ■vapor conducted on December 13,2001, at the referenced school.
The New York City Board of Education (BOE) requested this sampling at the recommendation of j
H. A. Bader, a consultant retained by the parents association.
Scope of Work
ATC collected three (3) samples each for metals and Hg at specified locations. Metal samples
were collected for eight (8) hours using 37 mm mixed cellulose ester filter coimected to battery-
powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and
after each sampling period. Two (2) samples were collected inside the building and one (1) was
collected on the roof. One blank sample was also submitted. Each sample was analyzed for a
panel of eleven (11) metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr),
cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo),
nickel (Ni) and zinc (Zn). A copy of the analytical report is attached. Analysis was performed by
NIOSH Methods 7300M.
ATC collected three (3) samples for mercury vapor using Carulite® (Hydrar) tubes connected to
battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. The samples
were collected at the same locations as those for metals.’ One blank tube was also submitted.
Analysis was performed by means of a mercury analyzer according to NIOSH Method 6009.
All samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene
Association-accredited laboratory in Reading, PA. A copy of the analytical report is attached.
The sampling locations, specified by the parent’s association consultant, were as follows:
• 1“ floor lobby;
• 2“** floor bridge entrance hallway;
• Roof by the air intake.
CONFIDENTIAL, CITY_21MC100_003432340
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240520
OCR can misread numbers and units. Confirm readings against the page image before using them.