NYC 9/11 Public Portal Document
104 East 25th Street
New York. New York 10010
wwwatc-enviro com
212 353 8280
Fax 212 353 8306
ASSOCIATES INC
January 10, 2002
Mr. Bernard P Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Metals & Mercury
High School for Leadership & Public Service (M894)
90 Trinity Place
New York, New York
ATC Project No. 15-19125-0290
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for metals and
mercury vapor collected on December 29, 2001, at the referenced school. The New York City
Board of Education (BOE) requested these samples to evaluate possible contamination in the
school building..
ATC collected nine (9) samples for metals and nine (9) samples for mercury vapor Samples
were collected for a minimum of ten (10) hours. Seven (7) samples were collected inside the
building and two (2) were collected outdoors for both analyltes One blank sample each was also
submitted The samples were sent to PSC Analytical Services, Inc., an American Industnal
Hygiene Association-accredited laboratory in Reading, PA. Copies of the analytical reports are
attached (Metals - Attachment 1; Mercuiy - Attachment 2)
Metal samples were collected using 37 mm mixed cellulose ester filters connected to battery-
powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and
after each sampling period. Analysis was performed by NIOSH Methods 7300M Each sample
was analyzed for a panel of eleven (11) metals. The metals were alummum (Al), cadmium (Cd),
chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn),
molybdenum (Mo), nickel (Ni) and zinc (Zn).
Samples for mercury vapor were collected using Carulite® (Hydrar) tubes connected to battery-
powered sampling pumps calibrated to collect 0 2 liters of air per minute. Analysis was
performed by means of a mercury analyzer according to NIOSH Method 6009.
The locations of the samples for both metals and mercury were; Roof by air intake. Outdoors by
the Mam Entrance; Library - 13* floor North; Room 1106-11* floor South, Room 903 - 9“’
floor North; Room 715-7* floor South; Room 503 - 5* floor North; Hallway by Stair 6-3"“^ floor
South; Mam Lobby - r‘ floor.
The established regulatory values for metals and mercury are intended for industrial workplace
exposures and are not generally applicable to office/school settings. There are no standards for
these materials in indoor air in non-industrial situations.
CITY_21MC100_003087733
NYC-WTC_000189687