NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan February 6, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDEL NES FOR AIR QUALITY PARAMETERS EVALUATED*
ii;.
IorgAnizatign
Respirable 65 micrograms per cubic
Particulates meter of air (pg/m^) 24 USEPA NPAAQS
(PM2.S) hour average
Respirable USEPA recommendation
Particulates 40 (xg/m^ 24 hour average for children/sensitive
(PMzd individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
KEAL-TIME SAMPLING RESULTS
A total of thirty-six (36) outdoor respirable particulates measurements* were
collected from sixteen locations in Manhattan, ranging from W. 21®' St. to E.
33'^'’ St. The measurements were made from 7:30 A.M. to 4:35 P.M. The lAQ
field report forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 13 pg/m^ to 28 pg/m^. The
indoor concentrations ranged from 10 pg/m^ to 25 pg/m^. None of the indoor
and outdoor readings were above the NPAAQS of 65 pg/m^ or above the EPA
recommended guideline for children and sensitive individuals of 40 pg/m^.
• These measurements were instantaneous readings,* the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, all readings, both indoors and outdoors, were
below the applicable EPA standard.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education, If you have any questions about this report,
please call (212) 353-8280, extension 212 or 261.
Sincerely,
ATC ASSOCIATES INC.
Uriannis Efstathiou James R. Cohn, CIH, CSP
Project Manager Regional Manager,
Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_2IMC10 0_0 0 34 22 981
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239941