NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 24, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No, 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
a»RAMET^t;i|/iaiSiGET LEVEL.; AGENCY -Yj-
Respirable 65 micrograms per cubic
Particulates meter of air (pg/m^) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 pg/m3 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West Iph Street to East 33’'* Street, The
measurements were made from 5:53 A.M. to 4:24 P.M, The lAQ field report
forms are provided as the Attachment,
The outdoor PM2 5 concentrations ranged from 37 pg/m^ to 94 pg/m^ with an
average of 69 pg/m^. The indoor concentrations ranged from 12 pg/m^ to 71
pg/m ’ with an average of 48 pg/m-C One (1) of the indoor and twenty-four (24)
of the outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average
concentration of particulate matter 2.5 micrometers or less in aerodynamic
diameter. Twenty-three (23) of the indoor and thirty-three (33) of the outdoor
readings were above the USEPA recommended guideline for children and
sensitive individuals of 40 pg/m'f
* These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, one (1) of the indoor and twenty-four (24) of the
outdoor readings were above the NPAAQS of 65 pg/nU 24-hour average
concentration of particulate matter 2,5 micrometers or less in aerodynamic
diameter. Twenty-three (23) of the indoor and thirty-three (33) of the outdoor
readings were above the USEPA recommended guideline for children and
sensitive individuals of 40 pg/m^.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC-ASSOCIATES INC. Revil
Arrtel Javaij James R. Cohn, CIH, CSP
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_003422739
SUBJECT TO PROTECTIVE ORDER NO, 2, SEPT, 2008
NYC-WTC_000239893
OCR can misread numbers and units. Confirm readings against the page image before using them.