NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 17, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
MS:/jiaRGET.LEVEtW^
Respirable 65 micrograms per cubic
Particulates! meter of air (pg/m^) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty (30) indoor and thirty-five (35) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11“* Street to East 33"! Street. The
measurements were made from 5:55 A.M. to 4:36 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 27 pg/m^ to 61 pg/m^ with an
average of 45 pg/m^. The indoor concentrations ranged from 14pg/m’ to 46
pg/m^ with an average of 35 pg/mL None of the indoor or outdoor readings
were above the NPAAQS of 65 pg/m^ 24-hour average concentration of
particulate matter 2.5 micrometers or less in aerodynamic diameter. Six (6) of
the indoor and twenty-three (23) of the outdoor readings were above the USEPA
recommended guideline for children and sensitive individuals of 40 pg/m^.
* These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, none of the outdoor readings were above the
NPAAQS of 65 pg/m’ 24-hour average concentration of particulate matter 2.5
micrometers or less in aerodynamic diameter. Six (6) of the indoor and twenty-
three (23) of the outdoor readings were above the USEPA recommended
guideline for children and sensitive individuals of 40 pg/m^.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC ASSOCIATES INC. Reviewed by:
•nel Javm James R. Cohn/UlH, CSP ’
Senior F^ject Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_003422689
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239883
OCR can misread numbers and units. Confirm readings against the page image before using them.