NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 16, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
Respirable 65 micrograms per cubic
Particulates meter of air (pg/m3) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 |4,g/m3 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 11*** Street to East 33"’ Street. The
measurements were made from 5:53 A.M. to 4:20 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 16 pg/m3 to 29 pg/m3 with an
average of 22 pg/uP. The indoor concentrations ranged from 12pg/m3 to 24
pg/m3 with an average of 17 pg/m\ None of the indoor or outdoor readings
were above the NPAAQS of 65 pg/m3 24-hour average concentration of
particulate matter 2.5 micrometers or less in aerodynamic diameter and the
USEPA recommended guideline for children and sensitive individuals of 40
gg/m^.
These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, none of the indoor or outdoor readings were
above the NPAAQS of 65 pg/m3 24-hour average concentration of particulate
matter 2.5 micrometers or less in aerodynamic diameter or above the USEPA
recommended guideline for children and sensitive individuals of 40 pg/m3.
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC ASSOCIATES INC. Reviewed by:
Arnel James R. Cohn, CIH, CSP
Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_2IMCl00_003422679
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239881
OCR can misread numbers and units. Confirm readings against the page image before using them.