NYC-WTC_000351415
ATC monitoring results for respirable particulates at lower Manhattan data (May 9, 2002).
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC report of monitoring at numerous NYC BOE sites on May 7, 2002.
NYC-WTC_000351411–000351412OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 9, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* ‘P(/yElAMB^ER 7:TARGET'LEVELiJ/ Respirable 65 micrograms per cubic Particulates meter of air (pg/m^) 24 hour USEPA NPAAQS (PM2.5) average Respirable USEPA recommendation Particulates 40 gg/m3 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates measurements* were collected from twenty-nine (29) school locations in Manhattan, ranging from West 11* Street to East 33''^ Street. The measurements were made from 5:50 A.M. to 4:28 P.M. The lAQ field report forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 27 pg/m^ to 42 pg/m^ with an average of 35 pg/m^. The indoor concentrations ranged from 25 pg/m^ to 38 pg/m3 with an average of 30 pg/m^. None of the indoor or outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Two (2) of the outdoor readings were above the USEPA recommended guideline for children and sensitive individuals of 40 pg/m^.
* These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.
CONCLUSION Based on our measurements, none of the indoor or outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Two (2) of the outdoor readings were above the USEPA recommended guideline for children and sensitive individuals of 40 pg/m^.
It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.
Sincerely, ATC ASSOCIATES INC. Reviewed
Yiannis Efstathiou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_003018039
NYC-WTC_000351412
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000351415
ATC monitoring results for respirable particulates at lower Manhattan data (May 9, 2002).
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351441
ATC reports real-time respirable particulates monitoring conducted Jun 3, 2002 for NYC Board of Education.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351427
ATC monitoring results for May 22–23, 2002 at NYC BOE sites.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208012
Letter reporting real-time air monitoring results for respirable particulates at lower Manhattan schools on June 5, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315927
Real-time respirable particulates monitoring at BOE sites, May 17, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315925
Real-time respirable particulates monitoring across NYC locations, May 16, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351455
ATC reports real-time respirable particulates monitoring conducted Jun 14–15, 2002 for NYC Board of Education.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351425
ATC report of respirable particulates monitoring at multiple NYC BOE locations (May 21, 2002).
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239870
ATC Associates report on respirable particulate air monitoring at NYC Board of Education locations for lower Manhattan comparison.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239882
ATC Associates report on respirable particulate air monitoring at NYC Board of Education locations for lower Manhattan comparison.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208008
Letter reporting real-time air monitoring results for respirable particulates at lower Manhattan schools on May 9, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315913
Real-time respirable particulates monitoring across NYC BOE sites, May 8, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000239870
ATC Associates report on respirable particulate air monitoring at NYC Board of Education locations for lower Manhattan comparison.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351415
ATC monitoring results for respirable particulates at lower Manhattan data (May 9, 2002).
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351441
ATC reports real-time respirable particulates monitoring conducted Jun 3, 2002 for NYC Board of Education.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239882
ATC Associates report on respirable particulate air monitoring at NYC Board of Education locations for lower Manhattan comparison.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351427
ATC monitoring results for May 22–23, 2002 at NYC BOE sites.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315982
Real-time respirable particulates monitoring at NYC BOE locations, June 18, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000351415
ATC monitoring results for respirable particulates at lower Manhattan data (May 9, 2002).
Similar indexed content
NYC-WTC_000351441
ATC reports real-time respirable particulates monitoring conducted Jun 3, 2002 for NYC Board of Education.
Similar indexed content
NYC-WTC_000351427
ATC monitoring results for May 22–23, 2002 at NYC BOE sites.
Similar indexed content
NYC-WTC_000208012
Letter reporting real-time air monitoring results for respirable particulates at lower Manhattan schools on June 5, 2002.
Similar indexed content
NYC-WTC_000315927
Real-time respirable particulates monitoring at BOE sites, May 17, 2002.
Similar indexed content