NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Laboratory spike recovery results, wipe matrix, October 2002

Machine-extracted title · confidence 90%

Lab report documenting Method 8290 analysis of a spike sample (SPIKE-2232) for quality control verification.

NYC-WTC_000239654–000239656
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street - Suite 200 Minneapolis. MN 55414

'^ce Analytical'____________ Method 8290 Laboratory Control Spike Results Tel: 612-607-1700 Fax- 612- 607-6444

Client - ATC ASSOCIATES

Lab Sample ID SPIKE-2232 Filename U21008B_01 Matrix WIPE Total Amount Extracted 1.00 m2 Dilution NA ICAL Date 08/06/2002 Extracted 09/29/2002 CCal Filename(s) U21008A_17 & U21008B_16 Analyzed 10/08/2002 21;33 "I Method Blank ID BLANK-2231 Injected By MRO

Native Qs Qm % Internal ng's Percent Isomers (ng) (ng) Rec, Standards Added Recovery

2,3.7,8-TCDF 0.20 0,19 97 2,3,7,8-TCDF-13C 2.00 76 2,3,7,8-TCDD-13C 2.00 75 1,2,3,7.8-PeCDF-13C 2.00 81 2,3,7,8-TCDD 0.20 0.19 96 2,3,4,7,8-PeCDF-13C 2.00 82 1,2,3,7,8-PeCDD-13C 2.00 80 1,2,3,4,7,8-HxCDF-13C 2.00 86 1,2,3,7,8-PeCDF 1.00 1.00 100 1,2,3.6,7,8-HxCDF-13C 2.00 91 2,3,4,7,8-PeCDF 1.00 0.98 98 2,3,4,6,7,8-HxCDF-13C 2.00 87 1,2,3,7.8,9-HXCDF-13C 2.00 87 1,2,3,4,7,8-HxCDD-13C 2.00 94 1,2,3,7,8-PeCDD 1.00 0.99 99 1,2,3,6,7,8-HxCDD-13C 2.00 81 1,2,3,4,6,7,8-HpCDF-13C 2.00 77 1,2,3,4,7,8,9-HpCDF-13C 2.00 73 1,2,3,4,7.8-HxCDF 1.00 0.97 97 1,2,3,4,6,7,8-HpCDD-13C 2.00 69 1,2,3.6,7,8.HxCDF 1.00 0.84 84 OCDD-13C 4.00 63 2,3,4.6,7,8-HxCDF 1.00 1.00 100 1,2,3,7,8,9-HxCDF 1.00 1.00 100 1,2,3,4-TCDD-13C 2.00 NA 1,2,3,7,8,9-HxCDD-13C 2.00 NA

1,2,3,4.7,8-HxCDD 1.00 1.00 100 2,3,7,8-TCDD-37CI4 0.20 79 1.2,3.6.7.8-HxCDD 1.00 0.97 97 1.2,3,7,8,9-HxCDD 1.00 1.02 102

1,2,3,4,6,7,8-HpCDF 1.00 1.03 103 1,2,3,4,7,8,9-HpCDF 1.00 1.03 103

1,2,3.4,6,7,8-HpCDD 1.00 1.17 117

OCDF 2.00 2.52 126 OCDD 2.00 3.68 184 P

Qs = Quantity Spiked Qm = Quantity Measured Rec. = Recovery (Expressed as Percent) P = Recovery outside of target range X = Background subtracted value Nn = Value obtained from additional analysis NA = Not Applicable * = See Discussion Report No.... 1061946

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, CITY_21MC1OO_OO3431193

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000239654

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000239654Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →