NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
iw
^ace Analytical____________
Method 8290 Laboratory Control Spike Results
. Tel: 612-607-1700
FaxL612-607-R444
Client - ATC ASSOCIATES
Lab Sample ID SPIKE-2232
Filename U21008B_01 Matrix WIPE
Total Amount Extracted 1.00 m2 Dilution NA
ICAL Date 08/06/2002 Extracted 09/29/2002
CCal Filenamefs) U21008A_17 & U21008B_16 Analyzed 10/08/2002 21:33
Method Blank ID BI_ANK-2231 Injected By MRO
Native Qs Qm % Internal ng's Percent
Isomers (ng) (ng) Rec. Standards Added Recovery
2,3,7,8-TCDF 0.20 0.19 97 2,3,7,8-TCDF-13C 2.00 76
2,3,7,8-TCDD-13C 2.00 75 -
1,2,3,7,8-PeCDF-13C 2.00 81
2,3,7,8-TCDD 0.20 0.19 96 2,3,4,7,8-PeCDF-13C 2.00 82
1,2,3,7,8-PeCDD-13C 2.00 80
1,2,3,4.7,8-HxCDF-13C 2.00 86
1,2,3,7,8-PeCDF 1.00 1.00 100 1,2,3,6,7,8-HxCDF-13C 2.00 91
I 2,3,4,7,8-PeCDF 1.00 0.98 98 2,3,4,6,7,8-HxCDF-13C 2.00 87
1,2,3,7,8,9-HxCDF-13C 2.00 87
1,2,3,4,7.8-HXCDD-13C 2.00 94
1,2,3,7,8-PeCDD 1.00 0.99 99 1,2,3,6,7,8-HxCDD-13C
1,2,3,4,6,7,8-HpCDF-13C
1,2,3,4,7,8,9-HpCDF-13C
2.00
2.00
81
77
73
I
1,2,3,4,7,8-HxCDF 1.00 0.97 97 1,2,3,4,6,7,8-HpCDD-13C 2.00 69
1,2,3,6,7,8-HxCDF 1.00 0.84 84 OCDD.-13C 4.00 63
2,3,4,6,7,8-HxCDF 1.00 1.00 100
1,2,3,7,8,9-HxCDF 1.00 1.00 100 1,2,3,4-TCDD-13C 2.00 NA
1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 1.00 1.00 100 2,3,7,8-TCDD-37CI4 0.20 79
1,2,3,6,7,8-HxCDD 1.00 0.97 97
1,2,3,7,8,9-HxCDD 1.00 1.02 102
1,2,3,4,6,7,8-HpCDF -1.00 1.03 103
1,2,3,4,7,8,9-HpCDF 1.00 1.03 103
1,2,3,4,6,7,8-HpCDD 1.00 1.17 117
OCDF 2.00 2.52 126
OCDD 2.00 3.68 184 P
Qs = Quantity Spiked
Qm = Quantity Measured
Rec. = Recovery (Expressed as Percent)
P = Recovery outside of target range
X = Background subtracted value
Nn = Value obtained from additional analysis
NA = Not Applicable
• = See Discussion Report NO.....1062004
! REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC1OO_OO343O852
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239018
OCR can misread numbers and units. Confirm readings against the page image before using them.