NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 09-10-02
CLIENT: NYC BOE
PROJECT ADDRESS: PS 124M / 40 Division Street
NY. NY
PROJECT NO: 41617-0907
SAMPLED BY: M. Nakhumovich
SAMPLE DATE: 09-10-02
DATE RECEIVED: 09-10-02
DATE ANALYZED: 09-10-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED; Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(gg/ft^)
01 9986 First Floor Lobby Floor <9.0 9,0
02 9986 Cafeteria Floor <9.0 9.0
03 9986 Auditorium Floor <9.0 9.0
04 9986 Classroom #205 Floor <9.0 9.0
05 9986 Classroom #307 Window Sill <7.0 7.0
06 9986 3rd Floor Hallway by Rm #307 Floor <9.0 9.0
07 9986 2nd Floor Hallway by Rm #205 <9.0 9.0
08 9986 1st Floor Hallway by Rm #107 <9.0 9.0
09 9986 1st Floor Hallway by Rm #113 <9.0 9.0
10 9986 Blank <9.0 gg 9.0 gg
11 9986 Blank <9.0 gg 9.0 gg
NOTE J:
THE REPORTING LIMIT (RL) IS 18.0 gg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 gg/fV, Window sills 250 gg/fP,
Window wells 400 gg/fP, Exterior surfaces 800 gg/fP.
NOTE 3: i
Blank units are in gg
CONFIDENTIAL, CITY_21MC100_003430809
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238993