NYC 9/11 Public Portal Document
104 East 25th St
New York. New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
ASSOCIATES INC.
March 18,2002
Mr. Bernard P. Orlan
Director. Ennronmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Silica Dust
Stuyvesant High School
ATC Project No. 15-19125-0246
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for silica-containing
dust conducted on February 27, 2002, at the referenced school. The New York City Board of
1
Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to
the parents association.
ATC collected a total of twelve (12) samples for respirable dust using pre-weighed 37mm PVC
filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to
deposition on the filters. Eleven (11) samples were collected inside the building and one sample
was collected outdoors. The samples were sent to PSC Analytical Services, Inc., an American
Industrial Hygiene Association accredited laboratory in Reading, PA. One blank filter was also
submitted. Analysts was performed by x-ray diffraction according to NIOSH Method 7500. A
copy of the analytical report is attached.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City
office, conducted the sampling. Sampling was conducted consistent with accepted industrial
hygiene practices. The results represent the conditions on the day the samples were collected.
Silica was not found above the limits of detection in any of the twelve samples.
ATC appreciates the opportunity to provide this indoor air quality consultative service to the
BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
ATC Associates, Inc,
James R. Cohn, CIH, CSP
Regional Manager, Industrial Hygiene Division
Attachment
CONFIDENTIAL, CITY_21MC100_003429719
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238357
OCR can misread numbers and units. Confirm readings against the page image before using them.