NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________
Method 8290 Analysis Results
Tel: 612-607-1700
Fax- 612- 607-6444
Client - ATC
Client's Sample ID ATC-0301-STY-DX-3
Lab Sample ID 103363750
Filename F20318B_14
Injected By MASB
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/01/2002
ICAL Date 01/24/2002 Received 03/05/2002
CCal Filename(s) F20318B_01 &F20318B_17 Extracted 03/12/2002
Method Blank ID BLANK-1505 Analyzed 03/19/2002 02:14
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0031 0.00200 BJ 2,3,7,8-TCDF-13C 2.00 60
Total TCDF 0.0280 0.00200 2,3,7,8-TCDD-13C 2.00 57
1,2,3,7,8-PeCDF-13C 2.00 59
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 59
Total TCDD 0.0420 0.00200 1,2,3,7,8-PeCDD-13C 2.00 56
1,2,3,4.7,8-HxCDF-13C 2.00 90
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 54
2,3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 63
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 67
1,2,3,4,7,8-HxCDD-13C 2.00 88
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 60
Total PeCDD 0.0300 0.01000 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 57
1,2,3,4,7,B,9-HpCDF-13C 2.00 55
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 64
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 49
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.0220 0.01000 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0,20 61
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD 0.0950 0.01000
1,2,3,4,6,7,8-HpCDF 0.0280 0.01000 J Total 2,3,7,8-TCDD
1,2.3.4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.0016 ng/m2
Total HpCDF 0.0450 0.01000 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0620 0.01000
Total HpCDD 0.1200 0.01000
OCDF 0.0270 0.02000 J
OCDD 0.3600 0.02000
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1054702
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003429603
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238282
OCR can misread numbers and units. Confirm readings against the page image before using them.