NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax' 612- 607-6444
Client - ATC
Client's Sample ID ATC-0301-234M-DX-2
Lab Sample ID 103363842
Filename U20325A_12
Injected By MASB
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/01/2002
ICAL Date 03/25/2002 Received 03/05/2002
CCal Filename(s) -020325A_07 & U20325A_20 Extracted 03/14/20-02
Method Blank ID BLANK-1516 Analyzed 03/25/2002 18:10
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0020 2.3,7,8-TCDF-13C 2.00 57
Total TCDF 0.0023 0.0020 J 2,3,7,8-TCDD-13C 2.00 66
1,2,3,7,8-PeCDF-13C 2.00 40
2,3,7,8-TCDD ND 0.0020 2,3,4,7,8-PeCDF-13C 2.00 37 P
Total TCDD 0.0460 0.0020 1,2,3,7,8-PeCDD-13C 2.00 49
1,2,3,4,7,8-HxCDF-13C 2.00 126
1.2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 57
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 97
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 71
1,2,3,4,7,8-HxCDD-13C 2.00 134
1.2,3,7,8-PeCDD 0.011 0.0100 I 1,2,3,6,7,8-HxCDD-13C 2.00 92
Total PeCDD 0.0730 0.0100 1,2,3.4,6,7,8-HpCDF-13C 2.00 81
1,2,3,4,7,8,9-HpCDF-13C 2.00 93 *
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3.4.6,7,8-HpCDD-13C 2.00 86
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 101 *
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.0360 0.0100 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 0.0270 0.0100 J 2,3,7,8-TCDD-37CI4 0.20 68
1,2,3,6,7.8-HxCDD 0.0150 0.0100 J
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.3300 0.0100
1,2,3,4,6,7,8-HpCDF 0.0280 0.0100 J Total 2.3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence; 0.0067 ng/m2
Total HpCDF 0.0740 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.1600 0.0100 B
Total HpCDD 0.4100 — 0.0100 B------
OCDF 0.0480 0.0200 J
OCDD 0.5800 0.0200 B
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7.8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 02-1054706
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003444427
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000177791
OCR can misread numbers and units. Confirm readings against the page image before using them.