^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax- 612- 607-6444
Client - ATC
Client's Sample ID ATC-0301-STY-DX-1
Lab Sample ID 103363735
Filename F20318B_12
Injected By MASB
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/01/2002
ICAL Date 01/24/2002 Received 03/05/2002
CCal Filename(s) F20318B_01 &F20318B_17 Extracted 03/12/2002
Method Blank ID BLANK-1505 Analyzed 03/19/2002 00:36
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 66
Total TCDF ND _ 0.00200 2,3,7,8-TCDD-13C 2.00 62
1,2,3,7,8-PeCDF-13C 2.00 67
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 66
Total TCDD 0.0026 0.00200 J 1,2,3,7,8-P6CDD-13C 2.00 64
1,2,3,4,7,8-HxCDF-13C 2.00 102
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 66
2,3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 78
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 86
1.2,3,4,7,8-HxCDD-13C 2.00 100
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 67
Total PeCDD ND 0.01000 1,2,3,4,6.7,8-HpCDF-13C 2.00 71
1,2,3,4,7,8,9-HpCDF-13C 2.00 71
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 79
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 72
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 73
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD 0.0440 0.01000 J
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.00054 ng/m2
Total HpCDF 0.0140 0.01000 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0330 0.01000 J
Total HpCDD 0.0820 0.01000 J
OCDF ND 0.02000
OCDD 0.2100 0.02000 B
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1054702
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003429601
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238280
OCR can misread numbers and units. Confirm readings against the page image before using them.