NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan January 7, 2002
Wipe Sampling for Dioxin Page 2
Stuvvesant High School (Manhattan) ATC Project No. 15-19125-0246
SUBSTANCE DESCRIPTION
“Dioxins” or “dioxin” is a name used for a group of chlorinated multi-ringed organic compounds
that includes polychlorinated dibenzo dioxins (PCDDs) and polychlorinated dibenzo furans
(PCDFs). They are related to polychlorinated biphenyls (PCBs). PCDDs and PCDFs are not
produced commercially except for research purposes. They occur as trace level by-products of
combustion and industrial chemical processes. Combustion of PCB-containing oils, such as
during an electrical transformer fire, is known to produce dioxins. Burning of some plastics may
also produce dioxins. Dioxins are toxic and are considered to be carcinogenic.
The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006
parts per million (ppm) as the allowable concentration of dioxin in soil. The Environmental
Protection Agency has a residential clean-up goal for dioxins of 1 part per billion (ppb). The
Occupational Safety and Health Administration (OSHA) has not established a Permissible
Exposure Limit (PEL) for dioxin on surfaces.
WIPE SAMPLING RESULTS
ATC submitted three wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. A
copy of the laboratory report is provided in Attachment 1. Samples were taken from areas
specified by the parents association consultant. The sample area for each sample was 1 square
meter (Im^). The areas sampled were:
• pt floor main entrance wall;
• 2^*1 floor bridge entrance wall;
• Mixed air plenum- AC #1
Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer
were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by
multiplying by an established equivalency factor (See Attachment). This provides a single value
(in nanograms) for the analytical results for each sample. A copy of the complete laboratory
report is attached. The results of the samples are shown in the following table.
DIOXIN WIPE SAMPLE RESULTS
(2,3, 7, 8 TCDD EQUIVALENTS)
FLOOR - HALLWAY 0.0022 ng/m2
2’^" FLOOR - HALLWAY 0.00032 ng/m2
MIXED AIR PLENUM - AC#1 0.0078 ng/m^
FIELD BLANK 0.00 ng/sample
CONFIDENTIAL, CITY_21MC100_003429391
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238234
OCR can misread numbers and units. Confirm readings against the page image before using them.