Lab report header, Stuyvesant HS wipe samples, 2002

Machine-extracted title · confidence 36%

ATC wipe-sample dioxin report for Stuyvesant HS; contamination evaluation.

NYC-WTC_000400720–000400722
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan January 15, 2002 Wipe Sampling for Dioxin Page 2 Stuwesant Hieh School (Manhattan) - ATC Project No. 15-19125-0246

SUBSTANCE DESCRIPTION

“Dioxins” or “dioxin” is a name used for a group of chlorinated multi-ringed organic compounds that includes polychlorinated dibenzo dioxins (PCDDs) and polychlorinated dibenzo furans (PCDFs). They are related to polychlorinated biphenyls (PCBs). PCDDs and PCDFs are not produced commercially except for research purposes. They occur as trace level by-products of ■ combustion and industrial chemical processes. Combustion of PCB-containing oils, such as during an electrical transformer fire, is known to produce dioxins. Burning of some plastics may also produce dioxins. Dioxins are toxic and are considered to be carcinogenic.

The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006 parts per million (ppm) as the allowable concentration of dioxin in soil.

WIPE SAMPLING RESULTS

ATC submitted three wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. A • copy of the laboratory report is provided in Attachment 1. Samples were taken from areas specified by the parents association consultant. The sample area for each sample was one square meters (Im^). The areas sampled were;

• ist floor main entrance wall; • 2^^^^ floor bridge entrance wall; • Mixed air plenum-AC#2 or AC #1

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by . multiplying by an established equivalency factor (See Attachment). This provides a single value (in nanograms) for the analytical results for each sample. The results of the samples are shown in the following table. DIOXIN WIPE SAMPLE RESULTS 2,3, 7, 8 TCDD EQUIVALENTS - Nanograms per square meter (ng/in-) I

0.000038 0.000032

0:00030 0.00062

0.015 0.0013 (AC #2) (AC #1)'

0.00 0.000023

CITY_21MC100_002896247

NYC-WTC_000400721

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000400721Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238239

Laboratory findings for polychlorinated dibenzo-p-dioxins and dibenzofurans from Stuyvesant High School wipe samples.

Similar indexed content

NYC-WTC_000238236

Results for PCDDs and PCDFs from wipe samples collected at Stuyvesant High School in December 2001.

Similar indexed content

Compare copies and versions →