NYC 9/11 Public Portal Document
.1
ATC Environmental, Inc.
104 East 25th Street
Mew York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHESA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.: 5741 - 62023
Ploorsl-12j]J^15,19
Date Received: 10/23/01 Grid Openings Analyzed;__ 4
Average Grid Opening :106;^0 uni
I Project Sample No.: 64-6
Air Volume: 1800 liters Total Area Analyzed: 0.0450 mra2
3
1 '1
Filter Type; MCE 25 mm diam., Pore Size: 0.45 urn
Effective Area: 335 mm2
Analytical Sensitivity: 22.2 3/mm2
0.0048 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 Struct/cc nom/mS
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
J
i Totals (All Structures)
The estimated uncertainty of this analysis is 1 standard deviation.
0 0 0.0 0.0000 N/A
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237462
OCR can misread numbers and units. Confirm readings against the page image before using them.