NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
.u With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Pinal Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
'•■'Yl
Project/Site: 40 Rector Street, 40 Rector st., NY. NY TEM Sample No.; 5741 - 62016
Floors 1-12, 14, 15, 19
Date Received; 10/23/01 Grid Openings Analyzed;__ 4
Project Sample No.: 57-S Average Grid Opening: 106,00 um
1 Air Volume: 1800 liters Total Area Analyzed: 0.0450 mm2
Filter Type; MCE 25 mm diam.. Pore Size; 0.45 um Analytical Sensitivity; 22.2 s/mm2
Effective Area; 385 mm2 0.0048 s/cc
3 FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
- 1 Total
single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5uni Struct/mm2 Struct/cc nqra/mS
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos {includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals {All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the methoc
Analyzed by; Report Reviewed by:
-1 ■ Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237455
OCR can misread numbers and units. Confirm readings against the page image before using them.