NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date; 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site; 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.: 5741 - 61983
Eloorsl-12,14,15jl9
Date Received; 10/23/01 Grid Openings Analyzed; 4
Project Sample No.; 24-11 Average Grid Opening; 106.00 um
Air Volume; ISSOliters Total Area Analyzed; 0.0450 mm2
Filter Type; MCE 25 mm dlam.. Pore Size; 0.45 um Analytical Sensitivity: 22.2 s/miii2
Effective Area; 385 nim2 0.0046 s/cc
FIBROUS PARTICULATES ANALYZED
Numb Observed CONCENTRATION
Total
single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0^ 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0-0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
ft Non-asbestos fiber i.d. (EDS/SAED): None detected
1 Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method
Analyzed by. Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
1 Director of Electron Microscopy
NYC-WTC_000237431
OCR can misread numbers and units. Confirm readings against the page image before using them.