New York, NY 10010 Report Date: 10/23/01
' ■ ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
, Sample Identification Analysis Parameters
ri Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No. :574i;6im
Floors 1-12, 14, IS, 19
Date Received: 10/23/01 Grid Openings Analyzed:__ 4
Project Sample No.: 22-12 Average Grid Opening: 106.00 um
Air Volume: 3^30Ut^ Total Area Analyzed: 0.04S0 mm2
. Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2
Effective Area: 385 mm2 0.0047 s/cc
FIBROUS PARTICULATES ANALYZED
Number observed CONCENTRATION
Total
Single Matrix Total. Struct. Filte Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/Tnm2 St3cuct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by. Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy