NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th' Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/19/01
'5 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 7S3), Vol, 52, No. 210, October 30. 1987
Sample Identification Analysis Parameters
UJ
Project/Site: 40 Rector Street, NY, NY TEM Sample No.: 5729 - 61853
Floors 16-16
Date Received:^X/19/01 Grid Openings Analyzed:__ 6
Project Sample No.: 08 Average Grid Opening: 106.00 um
Air Volume: 1300 liters Total Area Analyzed: 0.0674 mm2
Filter Type; MCE 25 mm diam., Pore Size; 0.45 um Analytical Sensitivity; 14.8 s/mm2
Effective Area; 385 min2 0.0044 s/cc
IFIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
C5 Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
n
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
n
■ Totals (All Structures) 0 0 0.0 o.ooco N/A
The estimated uncertainty of this analysis is 1 standard deviation.
n Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
M The Analysis was carried out in accordance with the approved TEM method.
! This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC_000237384