Asbestos TEM analysis data sheet, 40 Rector Street, Sep 2001

Machine-extracted title · confidence 90%

Technical data sheet recording transmission electron microscopy measurements and structural identification for air samples from September 24, 2001.

NYC-WTC_000237350
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Uj ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP 5554 - 09/24/01 Lab Sample No., 59456 Filter Type MCE 25 mm Operator Client Spl. No. 05-24-15 Filter Area 385 nim*2 i Instrument I.D. EM 10 CRX Grid I.D. Disk No.

Screen Magnification 16,400X (GO) Area 0.,01124 mm^2 Comments Acc. Voltage 8 0 kV No. GO to be Analyzed 6 ' 4.721 Struct. Corspd. to 70 s/mm'^2.) L.-J

Length I.D. of Structure EDS Nor,/ GO. structure Structure Type (Nonasb. No. >0.5 um No Coord. F B C M < 5 um :> Sum Chrys. Amphibole Nonasb. Ambig./ND Elements) f 7W Kvt. // /(

£ //

Photo No, (from 1 in 5 asbestos- identify all structures using EDS Chee c diffraction for asbestos store all unrepeated spectra containing samples) Grid acceptance:! structures up Ito ?0a/Am {1st 4) r“i <50% undiaaoivea finer, overlapped or' folded Struct. = > 0.5um & > 5:1 Aspect Ratio <10% particulate coverage >50% coverage Totals N= Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares <5% holes or opaque areas F B C M > Sum Positive diffraction pattern properties conforming to laboratory Identification criteria observed. •Unused portion For chrysotile: Q.73nm spacing for (020) renections, or filter Chrysotile a.a3nm spacing for the layer line repeat, streaking -Avoided portion of (110) and (130) reflections. □r filter For amphiboles; O.SSnm layer line repeat, and approx. (2mm wide) 3.5 ratio of non-twinned layer line spot spacing to Amphibole layer line repeat distance (0.53nm).

\/= EDS spectrum conforming to laboratory Ambiguous Fl identification criteria observed. AMPHIBOLES F= Single Fiber (1-3 intersections » 1-3 fibers) Amosite B= Bundle f>3 fibers <l fiber diameter apart) 25mm filter Crocidolite Non—asbestos C= Cluster (>□ Intersections) M= Matrix J SlQppinK Rules: I......... . Anthophyllite NSO= No Structures Detected >50 i/C.O. ar In lit 4 0.0. Tremolite Actinolite Non-Identified I.:\DATA\PRlVATE\MIXEC\CADD\3rEM3 9/32/98

Ui

NYC-WTC_000237350

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000237350Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270773

TEM analysis with EDS; multiple lab samples 62057-62068 documented.

Similar indexed content

Compare copies and versions →