NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos fiber analysis by TEM for 40 Rector Street, Sept

Machine-extracted title · confidence 95%

Laboratory report documenting asbestos fiber identification and quantification using transmission electron microscopy methods.

NYC-WTC_000237196
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 ■u

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 09/29/01

n ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: 7\HERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

1 Sample Identification Analysis Paraniecers

Project/Site: 40 Rector Street, NY, NY TEM Sample No. : 5579 - 5973.8 Foors 6, 7, 3, 4 11, 2, 1/Lobbv Date Received: 09/29/01 Grid Openings Analyzed:__ 6

Project Sample No.: T15 Average Grid Opening: 106.00 um

Air Volume: 1270 liters Total Area Analyzed: 0,0674 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analytical Sensitivity: 14.8 s/mm2 Effective Area: 385 mm2 0.0045 s/cc

---- --- ------- - ------ ——------ ; FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous str-uctures} 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 .0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The e.stimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected i Amphibole Asbestos Type: None detected UJ ___ _ ___ _________ ___ __ _________ _____ .--------------- --- The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. rn Director of Electron Microscopy

'1

NYC-WTC_000237196

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000237196Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →