ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol, 52. No. 210. October 30, 1987
: Sample Identification Analysis Parameters
U . ■ .
■Project/site: 4 0 Rector Street, HY, NY TEM Sample No.: 5579 - 59754
Foors 6, 7, 3, 4, 11, 2, l/Lobby
Date Received: 09/29/01 Grid Openings Analyzed:__ 6
r Project Sample No. : T31 Average Grid Opening: 106.00 -urn
air Volume: 1270 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Struct. > = 5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole.Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous ' 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 6.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
rn This laboratory is in compliance with the quality specified for the method.
UJ
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
1.-J