NYC-WTC_000236945
Report of indoor air quality measurements collected on January 24, 2002, at P.S. 89M.
11 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗Report of real-time air monitoring conducted on December 15-16, 2001, at P.S. 89M regarding environmental health.
NYC-WTC_000236917–000236922OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
104 East 25th Street
LTC 11
ASSOCIATES INC. New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306
December 19, 2001
Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008
Re: Real-Time Air Monitoring P.S.89M 201 Warren St. New York, New York ATC Project No. 15-19125-0297
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of the results of real-time air monitoring conducted on December 15-16,2001, at the referenced school. The New York City Board of Education (BOE) requested this monitoring at the recommendation of Environ Corp., the consultant to the parents association. *
SCOPE OF WORK
ATC assessed the basic indoor air quality (lAQ) parameters of temperature, relative humidity, carbon dioxide (CO2) and carbon monoxide (CO).
In addition, total volatile organic compounds (TVOCs), sulfur dioxide (SO2), hydrogen sulfide (H2S), nitric oxide (NO) and nitrogen dioxide (NO2) were also measured.
Respirable particulates (PM2.5) were monitored for 24 hours in three locations.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City office, conducted the assessment. ATC’s findings and conclusions are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.
ATC measured temperature, relative humidity, COj and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc.
ATC recorded concentrations of respirable particulates with a Dust Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc.
CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014659891
NYC-WTC_000236917
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000236945
Report of indoor air quality measurements collected on January 24, 2002, at P.S. 89M.
11 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236977
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 18, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236967
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 18, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236953
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 18, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400531
Real-time IAQ report for PS 89M covering Dec 15-16, 2001, by ATC Associates.
14 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383963
ATC reports real-time air monitoring results conducted December 15–16, 2001 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000325955
Memo presenting real-time air monitoring results for PS 89M, December 2001.
15 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208064
ATC Associates report on real-time air monitoring conducted at P.S. 89M in December 2001 to assess environmental conditions.
14 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
13 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396218
ATC monitoring report detailing real-time IAQ measurements at PS 234 following BOE request, Dec 8–12, 2001.
13 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373506
Real-time IAQ monitoring report for P.S. 234M in December 2001 and January 2002.
13 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000291841
Indoor air quality measurements report for 90 Trinity Place, May 2002.
10 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000400531
Real-time IAQ report for PS 89M covering Dec 15-16, 2001, by ATC Associates.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396218
ATC monitoring report detailing real-time IAQ measurements at PS 234 following BOE request, Dec 8–12, 2001.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245292
Notes and results from IAQ measurements at P.S. 89M; January 2002.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000259937
IAQ measurements collected Mar 8, 2002 for BOE
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236995
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 15, 2002.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000400531
Real-time IAQ report for PS 89M covering Dec 15-16, 2001, by ATC Associates.
Similar indexed content
NYC-WTC_000383963
ATC reports real-time air monitoring results conducted December 15–16, 2001 at the referenced school.
Similar indexed content
NYC-WTC_000325955
Memo presenting real-time air monitoring results for PS 89M, December 2001.
Similar indexed content
NYC-WTC_000208064
ATC Associates report on real-time air monitoring conducted at P.S. 89M in December 2001 to assess environmental conditions.
Similar indexed content
NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
Similar indexed content