Microscopy PCM fiber results for asbestos assessment at 100 Church Street.

NYC-WTC_000236338
Page image
Scanned page image, NYC-WTC_000236338
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sc'T^Job#: 203032204, \ 1 Of 1 C. .^Name: TRC Environmental Cofporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00017; New York City Law Department; 100 Church Street, AMBIENT Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Fields Fibers Density Cone. TWA Sample # Sample #/ Location Collected (liters/min.) (min.) (Fibers/mm^ ) (liters) (Fibers/cc) 01 GS031303ASBAIR2001 03/13/2003 6.3 420 2650.2 100 3 3.82 < 0.001 20th Floor Northwest Area 02 GS031303ASBAIR2002 03/13/2003 6.3 420 2650.2 100 3 3.82 <0.001 20th Floor Northeast Area 03 GSO313O3ASBA1RFBO1 03/13/2003 0 0 0 100 0.5 0.64 Field Blank Footnotes: / Reporting Notes: (1) Fibers/cc cannot bl I ill with no air volume. Analyzed by; Viclor Slopac AcjLZLj___ , Z'A-UT^^^'T&tC-SS^zed: 03/14/2003 Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15f94; Limit of Delection= 5.5 fibers per 100 fields or 7 Tibers/mmT; Blank analyses arc reported when available, however are not used to adjust results of associated samples in this report. Tliis rcpon rchilcE ONLY to the sample analysis expressed as fiberstsq mm of Tiller area: ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 inin2; TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=:0.'t5, New York samples (NYSDOH ELAP Lab# 11480); National Institute of Standards and Technology Accreditation requirements mandate that tliis report must not be reproduced except in full without tlic approval of tlie laboratory. A IHA # 102843.

o H

CO l-> S O o o I o

to cn ■ (JI co ro co

NYC-WTC_000236338

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000236338Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000236148

Laboratory report detailing phase contrast microscopy fiber results for ambient air samples from 100 Church Street.

Similar indexed content

Compare copies and versions →