Sci b#: 202032649 Pa of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / OSHA
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/15/02-STEL-0201 3/15/02 2 30 60 100 3 3.82 < 0.045
Mike Green
02 GS-3/15/02-STEL-0202 3/15/02 2 30 60 100 2 2.55 <0.045
Daniel Reilly
03 GS-3/15/02-STEL-0203 3/15/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
04 GS-3/15/02-STEL-0204 3/15/02 0 0 0 100 0.5 0.64
Blank Footnotes: ]
Reporting Notes:
(1) Fibers/cc cannot be calculated ‘Ei ir ;sj. ,with no air volume.
Analyzed by: Tatyana Grimchak Date Analyzed: 3/16/02
Samples analyzed by NIOSH 7400(AS4»f6^;&^SB£j2r-8rr3794; Limit of Detection= 5,5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed asfibers/sq mm of filter area: ND=No fibers observed: NA=Not
Analyzed; Walton-Beckett graticle field arfe =,= 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the O.OI fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIH A # 102843.