NYC 9/11 Public Portal Document
SciLa #: 202032411 *“6
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street/ Ambient
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered fields Fibers Density „ Cone. TWA
Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/13/02-STEL-0350 3/12/02 2 30 60 too 2 2.55 < 0.045
Ruben Reyes
02 GS-3/13/02-STEL-0351 3/12/02 2 30 60 100 3 3.82 <0.045
Ceasar Rodriguez
03 GS-3/13/02-STEL-0352 3/12/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
04 GS-3/13/02-STEL-0353 3/12/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot bt calculated for samples (or blanks) with no air volume.
Analyzed by; Devin Ahyee^________ ; Date Analyzed; 3/14/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94; Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed; NA= Not
Analyzed; Walton-Becketl graticle field area=0.00785 mm2.' TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% ceruinty of compliance with the 0.01 fibcr/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.