Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / OSHA
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/1/02-OSHA-STEL- 3/1/2002 2 30 60 100 0.5 0.64 < 0.045
Jose Ramon-STEL-0305
02 GS-3/1/02-OSHA-STEL- 3/1/2002 2 30 60 100 3 3.82 < 0.045
Wilfredo Ramirez-STEL-0306
03 GS-3/1/02-OSHA-STEL- 3/1/2002 0 0 0 100 0.5 0.64
Blank-Bl Footnotes: /
04 GS-3/1/02-OSHA-STEL- 3/1/2002 0 0 0 100 0.5 0.64
Blank-B2 Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot bet Ics, ir i) with no air volume.
Analyzed by: Anthony Hinton^ Date Analyzed: 3/2/2002
Samples analyzed by NIOSH 7400(A) MMIbod, llsue #2, 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sc mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area^Tr00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
O
1^
ro
___k
O
o
e
cn
CD
o
o
CD
NYC-WTC_000235650
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235650Source: NYC Law Department, mirrored locally