NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos air monitoring lab results, March 2002

Machine-extracted title · confidence 95%

Laboratory report detailing PCM fiber analysis for an asbestos air sample collected in March 2002.

NYC-WTC_000235310
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SciL^ob#: 202031963 Pa Of i t

Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; New York City Law Department; 100 Church Street / OSHA Flow Air Fiber Fibers SciLab Client Date Rate Duration Filtered Density Cone. TWA Fields Fibers Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

01 GS-3/8/02-OSHA-0335 3/8/02 2 300 600 62 103 211.63 0.136 Mike Green 02 GS.3/8/02-OSHA-0336 3/8/02 2 300 600 100 9 11.46 0.007 Wilson Bueno 03 GS-3/8/02-OSHA-0337 3/8/02 2 300 600 100 92 117.20 0.075 Mike Green 04 GS-3/8/02-OSHA-0338 3/8/02 2 300 600 100 3.5 4.46 < 0.004 Wilson Bueno 05 GS-3/8/02-OSHA-0339 3/8/02 0 0 0 100 0.5 0.64 Blank Footnotes: / 06 GS-3/8/02-OSHA-0340 3/8/02 0 0 0 100 0.5 0.64 Blank Footnotes; / Reporting Notes: (1) Fibers/cc cannot be calculated »rsi r blanks) with no air volume. Analyzed by; Tatyana Grimchafc Date Analyzed: 3/9/02 Samples analyzed by NIOSH 7400(A) MetfZ ;u^ k Limit of Detections 5.5 fibers per 100 fields or 7 fibers/nun2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0^785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: (ntralab Sr=0405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab# 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

O H

s o o 1^

Cn cn di.

N)

N YC-WTC_000235310

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235310Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.