SciL^feb#: 202021066
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00004; NYC Law Dept,; 100 Church Street (OSHA)
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Fields Fibers Density Cone. TWA
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 OSll 2/1/02 1.5 420 630 100 42 53.50 0.033
Anthony Lidsey
02 GS12 2/1/02 1.5 420 630 100 57 72.61 0.044
Mike Luna Footnotes: 7
03 GS13 2/1/02 0 0 0 100 0.5 0.64
Blank Footnotes: 2
04 0814 2/1/02 0 0 0 100 0.5 0.64
Blank Footnotes: 2
Reporting Notes:
(1) Moderat/tohsa^j Micul; mat! is presi on the filter which may obscure some fibers causing results with a low bias.
(2) fr ri^ri^^pwtttTio air volume.
AnalyzMby: Jonathan ; Date Analyzed: 2/2102
SamplesWl^d by NipSByt 1, 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett grata (60 area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of conblii ice with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandal that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.
NYC-WTC_000235568
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235568Source: NYC Law Department, mirrored locally