Asbestos air PCM results, 100 Church Street, Mar 2002

Machine-extracted title · confidence 95%

Laboratory report containing phase contrast microscopy fiber count data for ambient air monitoring at 100 Church Street.

NYC-WTC_000235555
Page image
Scanned page image, NYC-WTC_000235555
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Scil^l^b#: 202031961 ra 1 OI 4

ClienTName: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; New York City Law Department; 100 Church Street / AMBIENT *9

Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. TWA Fields Fibers Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

01 GS-3/8/02-ASB-0337 3/8/02 5 300 1500 too 6.5 8.28 0.002 Room 3-323A 02 GS-3/8/02-ASB-0338 3/8/02 5 300 1500 100 3 3.82 < 0.002 Room 3-323B 03 GS-3/8/02-ASB-0339 3/8/02 5 300 1500 100 15 19.11 0.005 Room 3-319 04 GS-3/8/02-ASB-0340 3/8/02 5 300 1500 100 8 10.19 0.003 Hallway Around Room 3-319 05 GS-3/8/02-ASB-0341 3/8/02 0 0 0 100 0.5 0.64 Blank Footnotes: 1 06 GS-3/8/02-ASB-0342 3/8/02 0 0 0 100 0.5 0.64 Blank Footnotes: / Reporting Notes: (1) Fibers/cc cannot be calculat^for iks) with no air volume. Analyzed by: Tatyana Grimchak_____ / - I________________ Date Analyzed: 3/9/02 Samples analyzed by NIOSH 7400(A) Method, Issue #2. 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fiber5/inm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed; NA= Not Analyzed; Walton-Beckett graticle field area = 0.00783 nun2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

NYC-WTC_000235555

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235555Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →