Client Name; TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street/ Ambient
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/13/02-ASB-0359 3/13/02 5 240 1200 too 2 2.55 <0.002
Rm 3-112
02 GS-3/13/02-ASB-0360 3/13/02 5 240 1200 100 1 1.27 < 0.002
Rm 3-111
03 GS-3/13/02-ASB-0361 3/13/02 5 240 1200 100 1 1.27 < 0.002
Rm-191
04 GS-3/13/02-ASB-0362 3/13/02 5 300 1500 100 3 3.82 < 0.002
Rm 3-190
05 GS-3/13/02-ASB-0363 3/13/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: /
06 GS-3/13/02-ASB-0364 3/13/02 0 0 0 100 0.5 0.64
Field Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot tecalculated for. samples (or blanks) with no air volume.
Analyzed by: Devin Ahyee nVviJZS.________ ; Date Analyzed: 3/14/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except io full without the approval of the laboratory. ARIA # 102843.
NYC-WTC_000235532
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235532Source: NYC Law Department, mirrored locally