Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; New York City Law Department; 100 Church Street / AMBIENT
Flow Air Fiber Fibers
SciLab Client Date Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (Uters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-3/1/02-ASB-0312 3/1/02 5 240 1200 100 2 2.55 < 0.002
WS 2-101
02 GS-3/1/02-ASB-0313 3/1/02 5 240 1200 100 5 6.37 < 0.002
WS 2-192
03 GS-3/1/02-ASB-0314 3/1/02 5 240 1200 100 8 10.19 0.003
RM 2-196
04 GS-3/1/02-ASB-0315 3/1/02 5 240 1200 100 4 5.10 < 0.002
RM 2-108
05 GS-3/1/02-ASB-B1 3/1/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
06 GS-3/1/02-ASB-B2 3/1/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
Reporting Notes:
(1) Fibers/cc cannot be es rifles) with-no air volume.
Analyzed by: Anthony Hinton Date Analyzed: 3/1/02
Samples analyzed by NIOSH Idtthod, Issui V15/94;'Unut of Detection^ 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA- Not
Analyzed; Walton-Beckett gratide field iea = 0.09'1785 Ipi2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fi1 r/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology