Client Name; TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; NYC Law Dept.; 100 Church Street, AMBIENT
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (Uters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-ASB-21302-0662 2/13/02 5 270 1350 100 45 57.32 0.016
6th Floor At WS-6-181a
02 GS-ASB-21302-0663 2/13/02 5 265 1325 100 1 1.27 <0.002
Sth Floor At WS-5-140
03 GS-ASB-21302-0664 2/13/02 5 240 1200 100 1.5 1.91 < 0.002
6thHoor At WS-6-173a
04 GS-ASB-21302-0665 2/13/02 5 240 1200 100 1.5 1.91 < 0.002
5th Floor At WS-5125
05 GS-ASB-21302-0666 2/13/02 0 0 0 100 0.5 0.64
Blank Footnotes: 1
06 GS-ASB-21302-0667 2/13/02 0 0 0 100 0-.5 0.64
Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot heYttUail^te^Jor (or blanks) with no air volume.
Analyzed by: Marvin Brothers \| * I : Date Analyzed: 2/14/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to the sample analysis expressed as fibers/sq mmof filter area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 rami; TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with tire 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.