Client Name; TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35053-0000-00007; NYC Law Dept.; 100 Church Street
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-13 2/5/02 3 30 90 100 8.5 10.83 0.046
Joshua Figueroa's S.T.E.L.
02 GS-14 2/5/02 3 60 180 100 4 5.10 <0.015
Daniel Reilly's S.T.E.L.
03 GS-15 2/5/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
04 GS-16 2/5/02 0 0 0 100 0.5 0.64
Blank Footnotes: /
Reporting Notes:
(1) Fibers/cc cannot be clid^lated for siwnfes (or/blanw) with no air volume.
Analyzed by. Lance Tuckruskye. j/pate Analyzed; 276/02
Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit Detection= 5.5 fibers per 100 fields or 7 fibers/mm2: This report relates ONLY to tire sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm?: IWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405. Interlab Sr=0.45. New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102S43.
O
L
R
o
I
o
to
Cn
cn
cn
to
co
NYC-WTC_000235354
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235354Source: NYC Law Department, mirrored locally