Asbestos air monitoring results, 100 Church Street

Machine-extracted title · confidence 95%

Laboratory report from TRC Environmental Corporation detailing PCM fiber analysis for air samples at 100 Church Street.

NYC-WTC_000235293
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sci] ob#: 202023407 P 1 Of 1 Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; New York City Law Department; 100 Church Street, OSHA Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Fields Fibers Cone. TWA Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc) 01 GS-2/22/02-OSHA-0633 2I221Q2 2 360 720 100 3 3.82 <0.004 Ceasar Rodriguez 02 GS-2/22/02-OSHA-0634 2/22/02 2 360 720 100 2 2.55 < 0.004 Ruben Reyes 03 GS-2/22/02-OSHA-0635 2/22/02 2.5 240 600 100 27 34.39 0.022 Ceasar Rodriguez 04 GS-2/22/02-OSHA-0636 2/22/02 2.5 240 600 100 2 2.55 <0.004 Ruben Reyes 05 GS-2/22/02-OSHA-B1 2/22/02 0 0 0 100 0.5 0.64 Blank Footnotes: 1 06 GS-2/22/02-OSHA-B2 2/22/02 0 0 0 100 0.5 0.64 Blank Footnotes: 1 Reporting Notes: (1) Fibers/cc cannot be calgulrrtetTfoi blpjlks)^idrtio air volume. Analyzed by: Tatyana Grimchak / / Analyzed; 2/23/02 Samples analyzed by NIOSH 7400(A) l(lethoa,'li 8/15/94: Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mni2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fibcr/cc standard: Estimated relative standard deviation: liiLralab Sr=0.405, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

o H K I NJ

S O O O I o

on on Ui

co

NYC-WTC_000235293

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235293Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →