1. January 11, 2002 ATC Associates letter deeming I.S. 89M safe for re-occupancy based on the analysis of forty-nine Transmission Electro Microscopy (TEM) samples conducted on January 10, 2002. The analysis was conducted in strict conformance with the methodology of the AHERA Einal Rule.
9 November 6, 2001 TEM analysis report of air samples from the entire 201 Warren Street building, which was performed in strict conformance with the methodology of the AHERA Einal Rule. Eess than 70 asbestos structures per mm’ were detected in all of the twenty-six interior ambient samples submitted from the site.
3. January 2002 limited lead-in-dust wipe sampling report for P.S. 89M, containing the results of twenty dust wipe samples from locations inside the school and three from the outdoor playground. These sites were indicated for testing by the Parents Association environmental consultant, Tom Fusillo of Environ. The samples were obtained by gently wiping a pre-measured surface area with non-alcohol moistened towelettes. Eaboratory analysis has shown that all samples collected contain lead below the floor and windowsill surface clearance guideline levels of 40p/ft’ and 250 P-g/fE respectively.
4. November 12, 2001 settled dust sampling for asbestos report for P.S. 89M. Thirty- three bulk and six soil samples were analyzed utilizing Polar Light Microscopy (PLM). A NYC-BOE representative on site indicated the locations and materials to be sampled. Furthermore, twenty-nine settled dust samples, utilizing the Scotch Magic Tape - An aid to the Microscopist for Dust Examination method by Gary Nichols, were collected from areas inside the school building where the collection of a bulk sample was not possible. These dust samples were also analyzed utilizing Polarized Light Microscopy (PLM). Analytical results indicated the presence of asbestos in the amount greater than 1% within the bulk sample collected from settled dust on soil. All other settled dust samples were found to contain either none or less than 1% asbestos. December 12, 2001 settled dust bulk sampling for asbestos report for P.S. 89M. Six settled dust bulk samples were analyzed using PLM. The samples were collected from locations indicated by NYC-SCA representatives. Two samples contained traces of asbestos fibers while the other four did not contain asbestos fibers. January 17, 2002 settled dust sampling for fiberglass report at P.S. 89M. Ten settled dust samples utilizing the 3M Scotch Magic Tape - An aid to the Microscopist for dust examination method, were collected. An Environ consultant indicated the ten locations where sample were taken. Analytical results indicated that none of samples contained fiberglass. January 22, 2002 respirable dust assessment report for P.S. 89M. The findings and conclusions are based on visual observations, the real-time environmental measurements and conditions present in the school at the time of the assessment. ATC recorded concentrations of respirable particulates (PM2.5) for 24 hours with a Dust-Trak Aerosol Monitor Model 8520. Samples of PM2.5 for gravimetric analysis were also collected for 24 hours using a Micro Environmental Monitor (MEM). The gravimetric samples were collected on pre-weighed P’VC filters. The assessment was performed with generally accepted indoor air quality assessment practices. Sample results were below EPA NPAAQS for PM2.5.
1
CITY_21MC100_012559417
NYC-WTC_000234707
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
9 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000180183
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in March 2002.
4 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000180188
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in April 2002.
4 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
10 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179972
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 8, 2002.
4 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175150
Letter and report from ATC Associates regarding indoor air quality measurements collected at DeSoto School in August 2002.
4 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179985
Letter from ATC Associates reporting indoor air quality measurements collected at a school on March 21, 2002.
4 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119373
Fax cover sheet regarding environmental activities at 125 Barclay Street.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000126257
Administrative label or header page identifying records associated with 10 Cortlandt Street.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
Similar indexed content
Similar indexed content
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in March 2002.
Similar indexed content
Cover letter from ATC Associates to the NYC Board of Education submitting indoor air quality measurements for 90 Trinity Place in April 2002.
Similar indexed content