NYC 9/11 Public Portal Document Jun 10 02 02: 1 Ip Aintek Envir-onmental Corp (212)758-0753 p 14 flPI^25-20Ba 14:33 SCl^TIFrC LABS. I -904 ?63 1800 P.03^03

L. Enwiroiimuntal Laboratory agivfces the SGiLAS Group of Laboratories _ 13635 areiito Food Mi*>iwan,VA2aiia 14^78£-1200 fax: 1^404-783-1603 _ iir fisM30th Street NawYoiK. NY 10016 1-2lfra78-B600 FAX: 1-2U-e7&-9aS2 _ 15 OtMsyHiDdva LMfttffl, NY 52110 1-SlB.786.ai00 PAX; IrSlB-TW-noO _ s School Street WByrroum, mA 02169 1-781-337.9334 FAX; 1.781'^7042 _ 244 l6a.M*> ffl, Su!l»30fi Canal. CA9074S l4lfl-«34-4a68 FAX: 1-310.834-4772

TcaDEDlsalon Electron Mic roscopy (TEM) is used to analyze samples which typically have fiben too tHa to be observed by PLM. Air samples are typically inalyztd for asbestos Qbars foliowing EPA (Level n and ASBRAJ, NYSDOH ELAP and NIOSH (#r;4O2) sddelinat. Bulk building materials are analyzed by FLM, howcvet T£M is often usr4 to analyze difficult bulk materials (floor tiles, plaster, mastic, etc) for asbestos content following modified Chatfield, NYSDOH ELAP (#198.4) and EPA (#€O0/R.?37116) methods. IHM alone is used for analysis of water samples for asbestos following EPA (600/4-83-043 said 600'4-80-003) guidelines. The EPA drinking water method is referred to as the EPA 100.2 method. Wliile debris sanies msy be analyzed by PLM, settled dust samples should be analyzed for by TEM using ASTM method S7S5. Settled JOust Evaluation (TEM) - Safe or “allowed'’ levels of asbestos in Settled Dust are not addressed by current leg) s lad on or mandated methodology. Settled dust evaluation is Tecommended by HPA documents such as the “Creen Sook” as a monitoring rnetliod for management programs. However, methods or “safe" levels an not addressed specifically. ASTM method D 3755 - 95 addresses microvac collection and TEM analysis of settled dust, with results provided in structures pcs unit area of surface (again, no indication of health risks are addrcsicd). In common experience, it is found that surface concentrations over the aSTM D 5755 required LDL (lower detection limit) of 1,000 asbestos striemS are considered elevated. Subsequent cleaning .by H£PA vacuuming and wet wiping commonly reduce measured dust levels to an order of tnagraiuda below the IDL or sensitivity level. SetU(»d Dust > Dnseriptlv* ContAmlnatlon I svels <I,OCO. stx/cm^ xiDL 1-10,000. stt/cni2 Slight 10-100,000. £tx/jw2 Modcntjc 100^000.1 MUImmj. stc/cm? Heavy; > 1 Million- stcfcn^ Extrcnti ll<7»TAM. . . ■ . ■ _______ ' AB0oC’75(55^iiM23S«D5BESSroTSCTwe5wJS3yS3r5t33S7MSI3i»o^»jKH!i;5n!Sw5y^^337^^ Ssciion u ijewmine ConipJeiwm of Reqtoiuc Actiooj^; Xiiphu&x A » Subpm 8, ^0 CfR pin 743. Ocwbsr W,19S7.

ASTM DS735-9S - “Mionvaevum SunpiiH wid locSml Aaatyua of by TnnwBia&iaa Eleemn Mienxeopj for A»t>esttt Filler ConceoBaUoa". Ajmtfkan Socieiy (br teuing and Mafcrittl!, 1916 Itacc St, Philadelphia. fA 19163. ETA level JI - Yamsrt C. Aaarwa) SC. ORibsni SO, 1.984 MolScSaJoDifor the of aiihMne HheOor hy eucuun nUerwOpy, Draft report. WajaiHgtao. Ofc OftSce of Toxic Suhs^nic^ U.S. EPA. rChntiaet tAi. 4ada-S2<fi.

R.1- Asd B.W, MarKcy. -^tmad Par ihe OatenalaadM-of ^steatoa i« Bui Bvlldlag MJOeriah’, SPA«tlWR- W116. ■ ■ ! ■'

TOTRL P.03

CITY_21MC100_002832775

NYC-WTC_000220175

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000220175Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →