NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 38 pages

NYC-WTC_000219925

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000219925–000219962
Page image
Scanned page image, NYC-WTC_000219935
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Search -1 Result - APPENDIX A TO SUBPART E - INTERIM TRANSMISSION EL... Page 11 of 38

sion) Duplicate analysis 1 per 100 samples 2 X Poisson std. (measure of repro­ Dev. ducibility) Known samples of Training and for 100% typical materials comparisons (working with unknowns standards) Analysis of NBS SRM 1 per analyst per 1.5 X Poisson Std. 1876 and/or RM year Dev. 8410 (measure of accuracy and comparability) Data entry review Each sample 95% (data validation and measure of completeness) Record and verify 1 per 5 samples 80% accuracy ID electron diffr action pattern of structure Calculations and Hand calculation of 1 per 100 samples 85% data reduction automated data reduction procedure or independent recal culation of hand- calculated data

1. When the samples arrive at the laboratory, check the samples and documentation for completeness and requirements before initiating the analysis.

2. Check all laboratory reagents and supplies for acceptable asbestos background levels.

3. Conduct all sample preparation in a clean room environment monitored by laboratory blanks. Testing with blanks must also be done after cleaning or servicing the room.

4. Prepare multiple grids of each sample.

5. Provide laboratory blanks with each sample batch. Maintain a cumulative average of these results. If there are more than 53 fibers/mm<2> per 10 200-mesh grid openings, the system must be checked for possible sources of contamination.

6. Perform a system check on the transmission electron microscope daily.

7. Make periodic performance checks of magnification, electron diffraction and energy dispersive X-ray systems as set forth in Table III and under Unit II.I.

8. Ensure qualified operator performance by evaluation of replicate analysis and standard

http ;//lexis/research/retrieve?_m=e 13 5f2ca3d266867c53d261 df3205722&_Imtstr=FULL<S... 02/04/2002 CITY_21MC100_012558675

NYC-WTC_000219935

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000219935Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →