Summary ofAsbestos Sampling Results Page 2 of 3 Address: J30 Water Street Date sampled: November 30, 2001

Results of Phase Contrast Microscopy (PCM) testing of air at 130 Water St., Nov. 30, 2001 Area Sampled Outside Common Residence 1 Residence 2 Residence 2 ==^== Sample Numbers A-0-24 A-C-24 A-Rl-24 A-R2-24 A-R2-24*

Concentration of Fibers in 0.002 0.001 0.001 0.005 0.005* Air at 130 Water Street (ficc)** Concentration of Fibers (f/cc) in comparison locations <0.001 toO.OOl <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003<0.001 to 0.003 NYC Re-occupancy 0.01 0.01 0.01 0.01 0.01 Standard (f/cc)*** * Denotes a second air sample taken in the same location for quality control purposes. ** f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air. *** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

Asbestos in air as determined by Transmission Electron Microscopy (TEM) analysis: TEM analysis is very specific and can distinguish between asbestos and non-asbestos fibers, such as textiles. This analysis determines if the fibers seen in the PCM analysis are asbestos, or if they are some other material. TEM analysis was conducted on all air samples that showed more than 0.003 f/cc in the air by PCM analysis. No asbestos fibers were found in the TEM analysis of these air samples. 2

Results of Transmission Electron Microscopy (TEM) testing of air at 130 Water St, Nov 30, 2001 llArea Sampled Residence 2 Residence 2

Sample Numbers A-R2-24 A-R2-24* Concentration of Asbestos Fibers in Air at 130 Water <0.001 <0.001 Street (Ecc)**_______________________________ Concentration of All Fibers (f/cc) in comparison < 0.001 to 0.003 <0.001 to 0.003 locations___________________________________ NYC Re-occupancy Standard (f/cc)*** 0.01 0.01 ^=s==s====s==^==s=:==ss=s=sss:s:s=^=^=^^^=^= ♦ Denotes a second air sample taken in the same location. f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. ***' New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

2 The TEM method employed here, NIOSH 7402, counts fibers of the same size as those detected by PCM analysis. Fibers reported here are greater than or equal to 5 microns in length and 0.2.5 microns in width.

CITY_21MC100_010212417

NYC-WTC_000208371

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000208371Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →