BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: OFFICE BLDG.- 2 Laffayette, Manhattan, NY
PROJLCTK:
7 9 10 1
Client Sample ID'r ■ 6 8
Lab Sample ID^ : 010917A-813 010917A-814 0109 PA-S 15 010917A-8i0 O10917A-SP
Sample Location: 12ih Floor 9th Floor 7t'h Floor Lobby 7th Floor 7(h Floor
Stair’W" Elevator Lobby By Elevator Stairway "Y" Stairs "W"
Homogeneity': Yes Yes Yes Yes Yes
Sample Description. Floor Floor Floor Floor Floor
V>'ipe Wipe Wipe Y' ipe W ipe
Colo- BIk Blk BIk Bik 01 <
Texpjre: Mixed Mixed Mixed Mixed .Mixed
Sample Treatment: None None None None None
Asbestos Present:
iTvpe & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% O’/o O’/o 0% 0%
Other Fibr. Mat.
(Tyve & Percent): 5T=CELL 5%CELL 5’/oCELL 5%CELL 8%CELL
5%SYNTH 5%SYNTH
Non Fibr. Mat.
(Percent) 95% 90% 95% 95% 87%
Date Received: 9N7/01
Date of Analysis. 9/17/01
Date of Report: 9/17/01
Analysis Lab ManaECr:
ouvaras David Chen
• Analysis of samples is oerformed bv Polarized Light Microscopv (PLM) - Point Countina Method
(EPA 600,744-82-020)
* Analytical eouipments: Stercobinocular microscope (MEIJI EMT-Sertal # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serialf# 88034)
• PLM is not consistently reliable Ln detecting asbestos in floor coverings and similar non-friable oraanicallv
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containine
' Samples will be stored for ninety (90) davs and then returned to the client upon rcouest
• The results relate only to the items calibrated or tested.
• The cenificate of reoon shall not be reproduced without the written approval of the laboratory.
* The report must not be used bv the client to claim endorsement bv NVLAP or any agency of the US Government,
NYS-DOH ELAP tf J]27J t\iSr-.\YLAP 102047 AfHA 100269