LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Window sills: 250 pg'fV
For Floors: 40 pg/ft^
For Exterior Concrete or Rough Surfaces: 800 pg/ft^
Although the lead-in-dust samples collected at P.S. 89M were not collected in response to
lead abatement, the same thresholds are used since no other regulations or standards are
applicable to this project.
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
(Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental
Protection Agency analysis method number SW846-7420 and the National Institute of
Occupational Safety and Health method number 7082M.
The lead-in-dust samples were obtained by gently wiping a pre-measured surface area
with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a
new glove was worn with each new sampling procedure, and care was taken to avoid
contamination of the towelette and collection vial, Towelettes were then placed into
50ml plastic vials and immediately sealed. The chain of custody form was completed and
documents the measurement of the area sampled.
Results of Dust Wipe Sampling
Forty (40) dust wipe samples were collected from areas indicated to ATC. Laboratory
analysis indicate that all dust wipe samples collected from the indicated areas contain lead
on floor, window sill and exterior concrete or rough surfaces below the guideline level of 40
pg/ft^ 250 pg/ft^and 800 pg/ft^ respectively. See laboratory report and chain of custody for
more details.
PS 89M
<S«rc
« •IOCI•! (t INC
November 11, 2002
CITY_21MC100_003058006