For Windowsills: 250 pg/fV
For Floors: 40 pg/lV
For Exterior Concrete or Rough Surfaces: 800 pg/fV
Although the lead-in-dust samples collected at P.S. 234M were not collected in response to
lead abatement, the same thresholds are used since no other regulations or standards are
applicable to this project.
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
(Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental
Protection Agency analysis method number SW846-7420 and the National Institute of
Occupational Safety and Health method number 7082M.
The lead-in-dust samples were obtained by gently wiping a pre-measured surface area
with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a
new glove was worn with each new sampling procedure, and care was taken to avoid
contamination of the towelette and collection vial. Towelettes were then placed into
50ml plastic vials and immediately sealed. The chain of custody form was completed and
documents the measurement of the area sampled.
Results of Dust Wipe Sampling
Thirty-three (33) dust wipe samples were collected from areas indicated to ATC.
Laboratory analysis indicates that all dust wipe samples collected from the indicated areas
contain lead on floor , windowsill and exterior concrete or rough surfaces below the
guideline level of 40 pg/ft’, 250 pg/ft^ and 800pg/ft^ respectively. See laboratory report
and chain of custody for more details.
Limits of the limited dust wipe sampling
Dust sampling was conducted at NYC-BOE request. The results of this report are
applicable for the time the testing was performed. If questions arise concerning lead
content in or on components and/or locations not tested by ATC, then additional testing
services should be procured. ATC makes no representation or wananty concerning the
standards and specifications provided in the HUD Guidelines and the NYC-BOE
protocol.
P.S 234M
STY March 25, 2002
CITY_21MC100_002878862