NYC 9/11 Public Portal Document
OCT. 18.2001 12^21^ JLC NO.876 P.2
J.O^RFCEMENT -ax:718-595-874^ Oct 17 ’Cl 10:5^ '-01
8 New York City Department of environmental Protection
Asbestos and Lead Control Program
Thank you for your response to our request for bids.
In order to simplify our contracting repuirements, please complete this bid sheet The seoioe of work la
included far your reference.
Company Name: JLC Environmtntal Consultants, Inc.
Addresu 200 Park Avenue South, Suite 1001
New York, NY 10003
Telephone: 212-420-8119
Fax: 212-420-6092
Contact: Ma. Jennifer Carey
JLC Environmental Consultants, Inc.
Laboratory Name:
Bid
Four Technicians (must possess valid NYS-DOL certification) ^^i^^^‘^.9dav
PCM analysis ^•Q^samplle
TEM analysis if PCM analysis above 0.01 f/cc TEM ahera 12 hr. 45.09samDle
TEM analysis TEM AHERA 12 hr. 45, QlfoaffiPls
Any other costs
Bignatura:
Scope of Work
Location and SampRng Type_________
1 Nameof^chool________ Looatloo _______
1. High School far Economics 5 Finance Between 90 & lOO trinity Place blent
27 ISW 201 \A/arran StreS 7^mbiant
IT hSzay 292 Oraenwich Street ~ ^tnblent
School 34j Chambers Street ~ "Ambient
1. Continuoussamplinfl for 8 hours at street level? f»arlodic oxamlnadon of flltersto ensumTlter does not
become overloaded. (Flew rata at 2.9 liters/rnln.; Minimum sampling volume 1200 liters.)
2. Sample analysis utilizing PCM NIOSH 7400 method. Samples found to be > 0.01 fZcc must be read
utWzing TEM AHERA method. There is a potential of changing analytical method to TEM only.
3. The PCM results shall be taxed to the NYC DEP (fax 718 595- 3744) by 0.00 a.m. the day after
sample collection. The TEM results shall be foxed to the NYCOEP within 12 hours of the PCM
reaidta.
4. Sampling shall continue daily until notification by the NYC DEP to terminate sampling. The sampling
is eetimetad to continue for 30 days.
5. NYCOEP contact information; R, Radhakrishnan (718) 595*3718 /Penny Theodoreliys (718) 995-3657