I New York City Department of Environmental Protection
As beetoe end Lead Control Program
Thank you for your reeponse to our request for bide.
-SCHL
In order to simplify our contracting requirements, please complete this bid sheet The scope of work ie
included for your reference.
Company Name: JLC Enviroiunent^lCoi^ltants, Inc.
Address: 200 Park'Avenue South, Suite 1001
New York, NY 10003
Telephone: 212-420-8119
Fax: 212-420-6092
Contact: Ms. Jennifer Carey
JLC Environmental Consultants, Inc.
Laboratory Name:
Bid
Four Technicians (must possess valid NYS-DOL certification) ^12^9day
PCM analysis _ ’^•Q^sample
TEM analysis if PCM analysis above 0.01 f/cc TEM AHERA 12 hr, 45.0j^ample
TEM anelyeis TEM AHERA 12 hr. AS.OteamDie
Any other costs
Sigrxiture: /
Scope of Work
Lo^tion and SampBng Type
Name of School
1. High School for Economics & Finance
Location
Between 90 & 100 Trinity Place
□ Type
Ambient
2. IS 89 201 Warren Street__________ Ambient
3. p's 234 282 Greenwich Street Ambient
13^/vcMntHigh School 345 Chambers Street Ambient
1. Continuous sam^lns for 8 hours at street level. Periodic examination of filters to ensure filter does not
become overloaded. (Flow rate at 2.S litera/mln.; Minimum sampling volume 1200 liters.)
2. Sample analysis utilizing PCM NIOSH 7400 method. Samples found to be > 0.01 f/cc must be read
utilizing TEM AHERA method- There is a potential of changing analytical method to TEM only.
3. The PCM resulta shall be faxed to the NYC DEP (fax 718 595- 3744) by 6:00 a.m. the day after
sample collection. The TEM resuHs shell be faxed to the NYCOEP within 12 hours of die PCM
resulta.
4. Sampling shall continue daily until notification by the NYC DEP to terminate sampling. The sampling
is estimated to continue for 30 days.
5. NYCOEP contact information. R. Radhakrishnan (718) 595-3718 /Penny Theodorellys (718) 505-3657
CITY_DEP_WORBY_CANNATA_SUBP_000045012
NYC-WTC_000182203