Bulk sample analysis report, 60 [name], Sept 2001

Machine-extracted title · confidence 90%

Laboratory report detailing bulk sample analysis results for asbestos at 60 [name] in September 2001.

NYC-WTC_000182336–000182340
Page image
Scanned page image, NYC-WTC_000182336
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36thStre«t Long Island City IP NewYork, 11106 Tel.(718)729.W k Fax: {718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC DCAS BUILDING ADDRESS: 60 Laffayette Street PROJECT#: Client Sample ID#; 1 9 3 4 5 Lab Sample ID# ; 010919A-1102 010919A-1103 010919A-1104 010919A-1105 010919A-1I06 Sample Location: Fan Machine Fan Machine Engineers Room Engineers Room Engineers Room Room Room 12th Floor 12 th Floor West 12th Floor 11th Floor 11th Floor

Homogeneity; Yes Yes Yes Yes Yes Sample Description: Filter Filter Window Sill Desk Cabinet Wipe Wipe Wipe

Color: Wh/Blk WBlk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

**** Asbestos Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% C'% 0% 0% Other Fibr. Mat. (Type & Percent); 90%FBGL 95%FBGL 2%CELL 5%SYNTH 5%SYNTH

Non Fibr. Mat. (Percent): 10% 50% 98% 95% 95% Date Received: 9/19/01 Date of Analysis: 9/19/01 Date of Report: 9/19/01

Analyst: Rood^ouis Lab Manager; David Chen * Analysis of samples is performed hv Polarized Light Microscopy (PLM) - Point Counting Method Q (EPA 600/M4-82-020) / * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscooy is currently the only method that can be used to determine if this material can be considered or treated as ncn-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. w NYS-DOH ELAP a 11273 MST-NVLAP a 102047 AIHA it: 100269

1

CITY_21MC100_006262422

NYC-WTC_000182336

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182336Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →