KAM CONSULTANTS
35-40 36thStre«t
Long Island City
IP NewYork, 11106
Tel.(718)729.W
k Fax: {718)729-1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC DCAS
BUILDING ADDRESS: 60 Laffayette Street
PROJECT#:
Client Sample ID#; 1 9 3 4 5
Lab Sample ID# ; 010919A-1102 010919A-1103 010919A-1104 010919A-1105 010919A-1I06
Sample Location: Fan Machine Fan Machine Engineers Room Engineers Room Engineers Room
Room Room 12th Floor 12 th Floor West 12th Floor
11th Floor 11th Floor
Homogeneity; Yes Yes Yes Yes Yes
Sample Description: Filter Filter Window Sill Desk Cabinet
Wipe Wipe Wipe
Color: Wh/Blk WBlk Blk Blk Blk
Texture: Mixed Mixed Mixed Mixed Mixed
Sample Treatment: None None None None None
**** Asbestos Present;
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% C'% 0% 0%
Other Fibr. Mat.
(Type & Percent); 90%FBGL 95%FBGL 2%CELL 5%SYNTH 5%SYNTH
Non Fibr. Mat.
(Percent): 10% 50% 98% 95% 95%
Date Received: 9/19/01
Date of Analysis: 9/19/01
Date of Report: 9/19/01
Analyst:
Rood^ouis
Lab Manager;
David Chen
* Analysis of samples is performed hv Polarized Light Microscopy (PLM) - Point Counting Method
Q
(EPA 600/M4-82-020) /
* Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscooy is currently the only method that can be used
to determine if this material can be considered or treated as ncn-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
w NYS-DOH ELAP a 11273 MST-NVLAP a 102047 AIHA it: 100269
1